003, Ethernet, SLIP, Telnet, and SNMP,Loop-AM3490 Access DCS-MUX  Manufacturers and 003, Ethernet, SLIP, Telnet, and SNMP,Loop-AM3490 Access DCS-MUX  Suppliers

  
Loop(suzhou)Technology Co., Ltd
Home > Product Category > Computer and Communication > Broadband & DSL Products > DSL Gateways





>> Company profile
>> View more products
Item Number:
003
Product Name:
Ethernet, SLIP, Telnet, and SNMP,Loop-AM3490 Access DCS-MUX 
Description:
The Loop-AM3490 is an access DCS-MUX that can combine various digital access interfaces into E1 or T1 lines for convenient transport and switching. The Loop-AM3440 Access DCS-MUX provides access for a variety of interfaces, including mini Quad E1, Quad E1/T1, ATM/ FR, 10/100baseT Router, FOM, MDSL, G.SHDSL, G.703, U type, X.21/V.11, V.35/V36, RS232, E&M, FXS, FXO and Magneto. These interfaces are compatible with other Loop products such as the Loop-H 3900 (MDSL), LoopH3300 and the Loop-U 3500 (U). Using these products, a DTE interface can be extended over copper wire pairs. For as many Quad E1/T1 plug-in cards, each card can have as many as 124 / 96 time slots for the G.shdsl, MDSL, U, RS232, X.21, V.36 and V.35 interfaces are then multiplexed to fill 4 E1 / T1 line, with full flexibility of time slot interchange for all incoming lines. AM3490 also supports fiber optical plug-in module, which can be used to aggregate up to 4 E1 channels to single fiber optical interface to connect with other AM3490 or O9310.

AM3490 has capacity for 12 single slots and 4 mini plug-in slots. All interface cards and controller cards can be used in 3490.

This unit is a full cross-connect and can act as a mini DACS. This means that one or more of the WAN ports can be used as a Drop & Insert function with fractional E1/T1 lines, which can be muxed into a full E1/T1 line.

Redundancy is available in dual CPU controller and power supply options, making it an excellent fit for critical applications. Although the chassis does not contain and has no need for fan cooling, an external fan tray is available.

The Loop-AM3490 supports local control and diagnostics by using an external 2-line by 40-character LCD display and keypads, or by using a VT-100 terminal connected to the console port. The Loop-AM3490 also supports Ethernet, SLIP, Telnet, and SNMP, so that it can be controlled and diagnosed from remote locations as well. An in-band management channel with GUI is available. In addition to the LCD display, there is LED indication for all plug-in cards.

Finally, the Loop-AM3490 consists of a rugged reinforced aluminum chassis, giving this equipment a more durable structure and a longer physical life.
Features:
Support of DS0 DACS (Digital Access Cross-Connect System) with full cross-connect
 Dual controller, dual power (?8V DC) with load sharing
 1 for 1 protection, Y-BOX
 1 for 1 protection, E1, T1, FOM
 PDH ring protection, QE1, QT1, FOM, Mini QE1
 Console, Telnet, SLIP, SNMP, and Inband management support
 Craft interface port for connection to external LCD display
 Compatible to a SNMP based GUI network management system and supported by LoopView and Loop iNMS
Specification:
Model (non RoHS compliant)


Model (RoHS compliant)


Description


Note

Main Unit







Loop-AM3490-CHA




Loop-AM3490-CHA-G


Wideband Main Unit without CPU, power, E1/T1 card


AM3440-A type Chassis

CPU Module










Loop-AM3490-CCA-T






Loop-AM3490-CCA-T-G


CPU card with T1 External Clock (order two for redundancy)


 

Loop-AM3490-CCA-E






Loop-AM3490-CCA-E-G


CPU card with E1 External Clock (order two for redundancy)

Mini Plug-in Module (Select 1 to 4 cards from list below)

Loop-AM3490-E1


Loop-AM3490-E1-G


E1 Interface




Loop-AM3490-T1


Loop-AM3490-T1-G


T1 Interface

Loop-AM3490-M4E75








Loop-AM3490-M4E75-G


Mini Quad E1 Interface

w/ 75 ohm






Includes a 1 meter DB25 to 8-BNC Conversion Cable

For AM3490-CHA and

Loop-AM3490-M4E120






Loop-AM3490-M4E120-G


Mini Quad E1 Interface

w/ 120 ohm




Includes a 1 meter DB25 to 4-RJ48C Jack Conversion Cable

Loop-AM3490-AFRE








Loop-AM3490-AFRE-G


E1 Frame Relay to ATM inter-working or

Frame Relay to Frame Relay concentration




Loop-AM3490-AFRT








Loop-AM3490-AFRT-G


T1 Frame Relay to ATM inter-working or

Frame Relay to Frame Relay concentration

Loop-AM3490-RT


Loop-AM3490-RT-G


Router / Bridge Card




Loop-AM3490-RTA
Loop-AM3490-RTA-G 64 WAN ports router/bridge card  

Loop-AM3490-FOM-OPT


Loop-AM3490-FOM-OPT-G


Fiber Optical Interface
 

Single Slot Plug-in Module

Loop-AM3490-4E1-cc




Loop-AM3490-4E1-cc-G


4-channel E1 Interface

where cc = RJ for RJ48C connector

BNC for BNC connector


 

Loop-AM3490-4T1


Loop-AM3490-4T1-G


4-channel T1 Interface

Loop-AM3490-6U


Loop-AM3490-6U-G


6-channel IDSL plug-in module




Loop-AM3490-10U


Loop-AM3490-10U-G


10-channel IDSL plug-in module




Loop-AM3490-3HA


Loop-AM3490-3HA-G


3-channel 6Mbits MDSL plug-in module without line power source (2Mbits per channel)
 

Loop-AM3490-2GH




Loop-AM3490-2GH-G


2-channel G.SHDSL plug-in module (2 pair)
 

Loop-AM3490-4GH




Loop-AM3490-4GH-G


4-channel G.SHDSL plug-in module (1 pair)
 

Loop-AM3490-8CD




Loop-AM3490-8CD-G


8-channel G.703 Interface at 64 Kbps data rate
 

Loop-AM3490-8DC




Loop-AM3490-8DC-G


8-channel dry contact I/O plug-in module
 

Loop-AM3490-8EM-x




Loop-AM3490-8EM-x-G


8-channel 2W/4W E&M plug-in module




Loop-AM3490-12FXS










Loop-AM3490-12FXS-G


12-channel FXS plug-in module with 600/ 900 Impedance, Battery Reverse, PLAR, without Ground Start and Metering Pulse
















12FXS cards are for use with 48VDC power module only.



12FXS-GM includes all function of FXS Cards, except 12FXS-P and 12FXS-GMP.











Loop-AM3490-12FXS-P












Loop-AM3490-12FXS-P-G


12-channel FXS plug-in module with 600/ 900 Impedance, Battery Reverse, PLAR, without Ground Start and Metering Pulse

PLAR bit programmable function

Loop-AM3490-12FXS-M








Loop-AM3490-12FXS-M-G


12-channel FXS plug-in module with 600/ 900 Impedance, Battery Reverse, PLAR, [Metering Pulse]

Loop-AM3490-12FXS-MP










Loop-AM3490-12FXS-MP-G


12-channel FXS plug-in module with 600/ 900 Impedance, Battery Reverse, PLAR and PLAR bit programmable function, [Metering Pulse]

Loop-AM3490-12FXS-GS








Loop-AM3490-12FXS-GS-G


12-channel FXS plug-in module with 600/ 900 Impedance, Battery Reverse, PLAR, [Ground Start]

Loop-AM3490-12FXS-GM








Loop-AM3490-12FXS-GM-G


12-channel FXS plug-in module with 600/ 900 Impedance, Battery Reverse, PLAR, [Ground Start, and Metering Pulse]

Loop-AM3490-12FXS-GMP












Loop-AM3490-12FXS-GMP-G


12-channel FXS plug-in module with 600/ 900 Impedance, Battery Reverse, PLAR and PLAR bit programmable function, [Ground Start, and Metering Pulse]

Loop-AM3490-12FXO








Loop-AM3490-12FXO-G


12-channel FXO plug-in module with 600/ 900 Impedance, Battery Reverse, without Ground Start and Metering Pulse




















12FXO-GM includes all FXO Card functions.

Loop-AM3490-12FXO-M








Loop-AM3490-12FXO-M-G


12-channel FXO plug-in module with 600/ 900 Impedance, Battery Reverse, [ Metering Pulse ]

Loop-AM3490-12FXO-GS






Loop-AM3490-12FXO-GS-G


12-channel FXO plug-in module with 600/ 900 Impedance, Battery Reverse, [ Ground Start ]

Loop-AM3490-12FXO-GM








Loop-AM3490-12FXO-GM-G




12-channel FXO plug-in module with 600/ 900 Impedance, Battery Reverse, [ Ground Start, and Metering Pulse ]

Loop-AM3490-12MAG-1G




Loop-AM3490-12MAG-1G-G


12-channel Magneto plug-in module with L1. GND








12MAG-1G2 includes all MAG Card functions.



Loop-AM3490-12MAG-12




Loop-AM3490-12MAG-12-G


12-channel Magneto plug-in module with L1, L2

Loop-AM3490-12MAG-1G2




Loop-AM3490-12MAG-1G2-G


12-channel Magneto plug-in module with L1, L2, and L1. GND

Loop-AM3490-1C37




Loop-AM3490-1C37-G


1- channel C37.94 plug-in module






Loop-AM3490-4C37




Loop-AM3490-4C37-G


4- channel C37.94 plug-in module

Loop-AM3490-ODP


Not available


8-channel OCU-DP plug-in module

Dual Slot Plug-in Module

Loop-AM3490-6X21A




Loop-AM3490-6X21A-G


6-channel X.21/V.11 card with DB15 connector






 

Loop-AM3490-6V35A










Loop-AM3490-6V35A-G


6-channel V.35 plug-in modules with DB25S connector, for M34 please order conversion cable connector below.

(2Mbits per channel)

Loop-AM3490-6V36A






Loop-AM3490-6V36A-G


6-channel V.36 card with DB25 connector via conversion cable to DB37

Loop-AM3490-6E530A




Loop-AM3490-6E530A-G


6-channel EIA530 card with DB25 connector

Loop-AM3490-6RS449A






Loop-AM3490-6RS449A-G


6-channel EIA530 card with DB25 connector via conversion cable to DB37

Loop-AM3490-5RS232




Loop-AM3490-5RS232-G


5-channel RS232 with X.50 subrate plug-in module




Loop-AM3490-24FXS





 


Loop-AM3490-24FXS-G


24-channel FXS plug-in module with /600/ 900 Impedance, Battery Reverse, PLAR, without Ground Start and Metering Pulse


24FXS-GM includes all function of FXS Cards, except 24FXS-P and 24FXS-GMP.



24FXS cards are for use with 48VDC power module only.

Loop-AM3490-24FXS-P












Loop-AM3490-24FXS-P-G


24-channel FXS plug-in module with 600/ 900 Impedance, Battery Reverse, PLAR, without Ground Start and Metering Pulse

PLAR bit programmable function

Loop-AM3490-24FXS-M








Loop-AM3490-24FXS-M-G


24-channel FXS plug-in module with 600/ 900 Impedance, Battery Reverse, PLAR, [Metering Pulse]

Loop-AM3490-24FXS-GS








Loop-AM3490-24FXS-GS-G


24-channel FXS plug-in module with 600/ 900 Impedance, Battery Reverse, PLAR, [Ground Start]

Loop-AM3490-24FXS-GM








Loop-AM3490-24FXS-GM-G


24-channel FXS plug-in module with 600/ 900 Impedance, Battery Reverse, PLAR, [Ground Start, and Metering Pulse]

Loop-AM3490-24FXS-GMP












Loop-AM3490-24FXS-GMP-G


24-channel FXS plug-in module with 600/ 900 Impedance, Battery Reverse, PLAR and PLAR bit programmable function, [Ground Start, and Metering Pulse]

Loop-AM3490-24FXO








Loop-AM3490-24FXO-G


24-channel FXO plug-in module with 600/ 900 Impedance, Battery Reverse, without Ground Start and Metering Pulse








24FXO-GM includes all FXO Card functions.









Loop-AM3490-24FXO-M








Loop-AM3490-24FXO-M-G


24-channel FXO plug-in module with 600/ 900 Impedance, Battery Reverse, [Metering Pulse]

Loop-AM3440-24FXO-GS




Loop-AM3440-24FXO-GS-G


24-channel FXO plug-in module with 600/ 900 Impedance, Battery Reverse, [Ground Start]

Loop-AM3490-24FXO-GM




Loop-AM3490-24FXO-GM-G


24-channel FXO plug-in module with 600/ 900 Impedance, Battery Reverse, [Ground Start, and Metering Pulse]

Loop-AM3490-3HAL














Not available


3-channel 6Mbits MDSL plug-in module with line power source












Factory installed option available with -48 Vdc powered chassis only.

Fan tray required.

For AM3490-CHA only

Loop-AM3490-2GHL




















Not available


2-channel G.SHDSL plug-in module with line power source (140 VDC, 110mA), (2 pair)
















Factory installed option available with -48 Vdc powered chassis only.

With line power, takes 2 DTE slots per card.

Fan tray required.

For AM3490-CHA only

Loop-AM3490-4GHL




















Not available


4-channel G.SHDSL plug-in module with line power source (190 VDC, 60mA), (1 pair)
















Factory installed option available with -48 Vdc powered chassis only.

With line power, takes 2 DTE slots per card.

Fan tray required.

For AM3490-CHA only

Power Module




Loop-AM3490-S5








Loop-AM3490-S5-G


Single ?8V DC Power Module (150W UM5613)






Order 2 single DC for dual DC application.



For AM3490-CHA only

Loop-AM3490-S524








Loop-AM3490-S524-G


Single ?4V DC Power Module (150W UM5603)






Cannot be used with FXS Card or MAG card.

For AM3490-CHA only

Loop-AM3490-SDB








Loop-AM3490-SDB-G


Single ?8V DC Power Module (100W)






Order 2 single DC for redundancy

For AM3490-CHB only

Adaptor




Loop-ACC-APA-150




Loop-ACC-APA-150-G


AC (100-240 Vac) to DC (48 Vdc = 3.3A) adaptor for USA




Loop-ACC-APE-150




Loop-ACC-APE-150-G


AC (100-240 Vac) to DC (48 Vdc = 3.3A) adaptor for Europe

Loop-ACC-APU-150




Loop-ACC-APU-150-G


AC (100-240 Vac) to DC (48 Vdc = 3.3A) adaptor for UK

Y-Box







Loop-VV-B




Loop-VV-B-G


1 for 1 protection Y-Box with BNC connectors (4-E1)


Used with 4E1

Loop-VV-R




Loop-VV-R-G


1 for 1 protection Y-Box with RJ48C connectors (16-E1)


Used with 4E1

Loop-VV-T




Loop-VV-T-G


1 for 1 protection Y-Box with RJ48C connectors (16-T1)


Used with 4T1


Safety Approval:
Dimensions 432.4 x 220 x 223.5 mm (WHD)
Power Single/ Dual -48V DC, 100 Watts max (DISCONTINUED).
Single/ Dual -48V DC, 150 Watts max.
Single/ Dual -24V DC, 150 Watts max
Temperature 0-50ķu 0-50ķu
Humidity 0-95%RH (non-condensing)
Mounting Desk-top stackable, 19?/23?rack mountable
Line Power Supply (For MDSL card and G.SHDSL card only) Available only with DC power.
Power Consumption Max 110 Watt
Other Description:

OPT = Description Note
SAA Single optical module with dual uni-directional fiber, 1310 nm,
SC optical connector, 30 km reach (20dB) - S1.1 Use dual fiber
Units delivered ITU-T G.957 application code
SBB Single optical module with dual uni-directional fiber, 1310 nm,
SC optical connector, 50 km reach (30dB) - L1.1
SCC Single optical module with dual uni-directional fiber, 1310 nm,
FC optical connector, 30 km reach (20dB) - S1.1
SDD Single optical module with dual uni-directional fiber, 1550 nm,
SC optical connector, 20 km reach (12dB) - S1.2
SEE Single optical module with dual uni-directional fiber, 1550 nm,
SC optical connector, 100 km reach (40dB) - L1.2
SSM Single optical module with single bi-directional fiber (master),
1310 nm transmit and 1550 receive, SC optical connector,
30 km reach (20dB) - S1.1/ S1.2 1310 nm from master to slave
Order SSM to use with SSS
Use 1 fiber
ITU-T G.957 application code
SSS Single optical module with single bi-directional fiber (slave),
1310 nm receive and 1550 transmit, SC optical connector,
30 km reach (20dB) - S1.1/ S1.2 1550 nm from slave to master
Order SSS to use with SSM
Use 1 fiber
ITU-T G.957 application code


For other optical modules:
MMSnn Other special optical modules for special order nn = 01 to 99
(contact sales for details)


where x is used to select ABCD signaling bits type:
x = Description Note
E Follows ETSI signaling bits  
A Follows ANSI signaling bits Jamper selectable for all channels
R Reverse for ON-HOOK and OFF-HOOK signaling bits exchange
S Follows customer̼ special bit or function assignment
AR Follows ANSI signaling bits and reverse bit

 
 
Send Message   (Your message will be sent directly) 
* Required information     
* Subject :
* Message :
Contact Information  
* Please enter check code:

I want to post this inquiry to AsianNet trade bulletin for more opportunities.
Register to become a member; list your company and products for free!

 
Sun Asia Enterprise Co.,Ltd     Wonpro Co., Ltd.      Cheng Tung Industrial Co., Ltd.
Home - Global Suppliers - Best Products - Trade InfoCenter
Copyright (c) 2008 AsianNet Inc. All Rights Reserved.