| Air Power Master International Corp. |
|
Item Number:
|
APM-RO-250/RO-500 |
|
Description:
|
Operation Pressure: 80 ~ 100 PSI ; "*" REMARKS FOR 150 ~ 220 PSI.
Rejection : 90 ~ 97%
Recovery Rate: 50 ~ 75%
Specifications
Model# |
Flow Rates
(GPD) |
R.O Modules Model x Numbers |
R.O Pump/Voltage |
Dimensions (cm)
(L x W x H) |
RO-250* |
250 |
2521X1 |
1/3HP,110V/220V |
36X52X118 |
RO-500* |
500 |
2521X2 |
1/3HP,110V/220V |
36X52X118 |
Feedwater Conditions
Inlet Pressure ------------- > 1.5 kg/cm2
Chlorine -------------- < 0.1 ppm
Total Hardness ----------- <10 ppm
Turbidity ------------- < 2 NTU
Fe ----------------------------- < 0.1 ppm
SDI -------------------- < 4
|
|
Features:
|
a. Automatically operates and PLC control device.
b. Automatic flush device.
c. Low-pressure protection switch.
d. Product Hi-level control.
e. Over - heat protection device for pump.
f. Concentrate recycle-flow regulator.
g. Digital feed/ product water quality meter.
h. Operating pressure set-up device.
i. Automatic power shut-off device if pre-treatment system is in regeneration process.
j. Chemical cleaning system.
k. All # SUS 304 made skids except the RS-series.
l. Includes one standard Hi-pressure R.O Pump; optional two parallel Hi-pressure R.O Pumps are also available.
|
|
|
|
|
|
|
 |
Send Message (Your message will be sent directly) |
|
|
|
|
|
|